Fuji G11 inverter maintenance - Hong Jia Wei can repair maintenance of Fuji G11 inverter: no display, lack of phase, overcurrent, overvoltage, undervoltage, overheating, overload, grounding, parameter error, output module, display without damage, replacement parts etc.. Please call the service hotline 0755-28916839, 13640994287, we have a professional customer service staff to quickly respond to your needs.
Description
Fuji G11 inverter repair
Model: Fuji G11-7.5KW FRN
Failure phenomenon: display in operation "OL1"
Fault analysis: OL failure overload alarm, according to the fault V phase current fluctuation of large motor loading test current detection, it was found that the V phase has a significant imbalance of three-phase drive detected by oscilloscope, measuring driving voltage of V phase is normal, replace the V phase driver after the test waveform is often. With load test 3 phase output current is normal. After the customer is now running normally.